燃氣發(fā)電機組對燃氣管道使用要求有哪些?
1、燃氣管道應采用鋼管,管壁不應太薄,接頭處要密封可靠,燃氣管線(xiàn)連接完成后,用燃氣檢測儀或肥皂水檢測管線(xiàn)滲漏情況,特別是法蘭、閥門(mén)等接頭處。
1. Gas pipelines should be made of steel pipes, and the pipe wall should not be too thin. The joints should be sealed reliably. After the gas pipeline connection is completed, the leakage of the pipeline should be detected using a gas detector or soapy water, especially at the joints of flanges, valves, etc.
2、應定期檢查燃氣發(fā)電機組的閥門(mén),應無(wú)燃氣泄漏、損壞等現象,閥門(mén)周?chē)鷳獰o(wú)妨礙閥門(mén)操作的堆積物,閥門(mén)應定期進(jìn)行啟閉操作和維護保養,無(wú)法啟閉或關(guān)閉不嚴的閥門(mén),應及時(shí)維修或更換。
2. The valves of the gas generator unit should be regularly inspected to ensure that there are no gas leaks, damage, or other phenomena. There should be no accumulation around the valves that hinders their operation. The valves should be regularly opened and closed for maintenance. Valves that cannot be opened or closed tightly should be repaired or replaced in a timely manner.
3、燃氣管線(xiàn)上的膠管應定期更換,嚴禁使用過(guò)期老化膠管。
3. The rubber hoses on the gas pipeline should be replaced regularly, and it is strictly prohibited to use expired and aged rubber hoses.
4、對燃氣發(fā)電機組及燃氣管線(xiàn)進(jìn)行運行、維護和搶修時(shí),必須可靠地切斷燃氣來(lái)源并將內部燃氣排凈,未查明事故原因和采取必要安全措施前,不得向燃氣設施恢復送氣。進(jìn)行維護檢修時(shí),應采取防爆措施或使用防爆工具,嚴禁用鐵器等工具進(jìn)行敲擊作業(yè)。
4. When operating, maintaining, and repairing gas generator units and gas pipelines, it is necessary to reliably cut off the gas source and exhaust the internal gas. Before identifying the cause of the accident and taking necessary safety measures, gas supply to gas facilities must not be restored. When carrying out maintenance and repair, explosion-proof measures should be taken or explosion-proof tools should be used. It is strictly prohibited to use tools such as iron tools for knocking operations.
5、燃氣泄漏的搶修應在切斷氣源后進(jìn)行,當泄漏處已發(fā)生燃燒時(shí),應先采取措施控制火勢后再切斷氣源,嚴禁管道內出現負壓。
5. The emergency repair of gas leaks should be carried out after cutting off the gas source. When the leak has already burned, measures should be taken to control the fire before cutting off the gas source. Negative pressure is strictly prohibited in the pipeline.
用戶(hù)在使用燃氣發(fā)電機組的時(shí)候對一些零部件的使用也要注意,只有這樣才能更好的使用燃氣發(fā)電機組。
Users should also pay attention to the use of some components when using gas generator sets, only in this way can they better use gas generator sets.